FHEM Server

define StromZ1 SML 192.168.178.20 

Wasseruhr Atair MCI

Gaszähler

Intelligenter Stromzähler EnBW ISZ

 http:192.168.47.212/InstantView/request/getPowerProfile.html?ts=0&n=5

XML-Ausgaben

<?xml version="1.0" encoding="UTF-8"?>
<values xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
      xsi:noNamespaceSchemaLocation="/InstantView/request/powerProfile.xsd">
    <header>
        <name>Wirkleistung</name>
        <obis>1.25.0</obis>
        <startts>190811094700s</startts>
        <endts>190811094705s</endts>
        <samplerate>1</samplerate>
        <no>5</no>
        <error>false</error>
    </header>
    <v>285</v>
    <v>285</v>
    <v>285</v>
    <v>285</v>
    <v>286</v>
</values>
  • getDateTime
<?xml version="1.0" encoding="UTF-8"?>
<values xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
      xsi:noNamespaceSchemaLocation="/InstantView/request/dateTime.xsd">
    <header>
        <name>DTM</name>
        <resformat>STD</resformat>
        <error>false</error>
    </header>
    <datetime>190811094225s</datetime> 
</values>
  • getIdentification
<?xml version="1.0" encoding="UTF-8"?>
<system xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
       xsi:noNamespaceSchemaLocation="/InstantView/request/identification.xsd">
    <header>
        <resformat>STD</resformat>
        <error>false</error>
    </header>
    <id>
        <upnp>Mein Zaehler</upnp>
        <meter>0323153980235004</meter>
        <meterType>wiki2std</meterType>
        <meterPurpose>Strom</meterPurpose>
        <fa/>
        <cpu>00901000023247</cpu>
        <mac>00:30:D6:06:8A:87</mac>
    </id>
    <version>
        <hw>10301</hw>
        <sw>WNGW000702</sw>
        <sys>DGUB010106</sys>
    </version>
    <supplier>
        <supplierid>enbw</supplierid>
    </supplier>
    <watchdog>
        <laststart>190810225343s</laststart>
        <bootcount>1057</bootcount>
    </watchdog>